HDPE reducing tee

Home » HDPE reducing tee

HDPE reducing tee

Raw Materials: PE100, PE100RC
Standards : EN12201, ISO 4427, AS/NZS 4129
Diameter: DN63-800mm (Larger size can be customized)
PressureRating: SDR9, SDR11, SDR13.6, SDR17
Certificates: UL, WRAS, NSF, ISO, CE
Color: Black, colors can be customized
Raw Materials: PE100, PE100RC
Standards : EN12201, ISO 4427, AS/NZS 412
Diameter: DN20-800mm (Larger size can be customized)
PressureRating: SDR9, SDR11, SDR17, SDR26
Certificates: CE, ISO, WRAS, UL
Color: Black, colors can be customized

Contact Us

product category

PP fitting
Welding Machine

HDPE (High Density Polyethylene) Butt Fusion is a high-strength, corrosion-resistant plastic pipe fitting designed for branch connection of HDPE pipe system, suitable for flow diversion or confluence of fluids with different pipe diameters. This product adopts hot-melt butt technology to ensure that the connection parts are leak-free and high-strength, and is widely used in municipal water supply and drainage, gas transportation, chemical pipelines, agricultural irrigation and other fields.

HDPE Hot melt reducing tee (1)
HDPE Hot melt reducing tee (1)

Core advantages

1. High-strength sealing – hot-melt butt welding fuses the pipe and pipe fittings into one, and the interface strength is ≥ the pipe body, eliminating the risk of leakage.

2. Corrosion and aging resistance – HDPE material is acid and alkali resistant, UV resistant, with a service life of up to 50 years, and can adapt to harsh environments.

3. Flexible adaptation of different diameters – supports different diameter combinations of main pipes and branch pipes (such as DN160×DN90×DN160) to meet the needs of complex pipe networks.

4. Lightweight and easy to construct – the weight is only 1/8 of that of metal pipe fittings, reducing transportation and installation costs.

HDPE Hot melt reducing tee (2)
HDPE Hot melt reducing tee (2)

Application areas

1. Municipal engineering: water supply network branching, sewage system transformation.

2. Gas transmission: variable diameter connection of medium and low pressure gas pipelines.

3. Industrial pipelines: chemical fluid distribution, factory network layout.

4. Agricultural irrigation: main and branch pipes with variable diameter and diversion, water saving and high efficiency.

Installation Guide

1. Cutting and Alignment: Use a special cutter to ensure that the pipe end is flat and aligned with the tee socket.

2. Heating and Welding: Use HDPE Buttfusion Welding Machine to heat the pipe and fittings to a molten state (210℃±10℃).

3. Butt Fusion and Pressure: Quickly butt and apply constant pressure to avoid movement during cooling.

HDPE Hot melt reducing tee (3)
HDPE Hot melt reducing tee (3)

HDPE reducing tee dimensions

dn-dn1LL1L2Hee2
SIZE(dn-dn1)mm mm mm mm SDR13.6SDR11
T75-50199705594 6.8*4.6
T75-632207065107 6.8*5.8
T90-5024380651156.7*3.78.2*4.6
T90-6324380681236.7*4.78.2*5.8
T90-7527080751306.7*5.68.2*6.8
T110-5024283601258.1*3.710*4.6
T110-6324283621308.1*4.710*5.8
T110-7527583801388.1*5.610*6.8
T110-9027583821403.2*6.710*8.2
T125-6330580701459.2*4.711.4*5.8
T125-7530580701459.2*5.611.4*6.8
T125-9030580751509.2*6.711.4*8.2
T125-11030580751509.2*8.111.4*10
T140-63253757015010.3*4.712.7*5.8
T140-75253757515510.3*5.612.7*6.8
T140-90253757515510.3*6.712.7*90
T140-110253708016010.3*8.112.7*10
T140-125320808016010.3*9.212.7*11.4
T160-50250907017011.8*3.714.6*4.6
T160-63278907517011.8*4.714.6*5.8
T160-75277907517011.8*5.614.6*6.8
T160-90272858517011.8*6.714.6*8.2
T160-1103331008017511.8*8.114.6*10
T160-1253809810019011.8*9.214.6*11.4
T160-14038310010019511.8*10.314.6*12.7
T180-63270857518013.3*4.716.4*5.8
T180-75270857518013.3*5.616.4*6.8
T180-90270858018013.3*6.716.4*8.2
T180-110270858518513.3*8.116.4*10.0
T180-160400908518513.3*11.816.4*14.6 
T200-63338957519514.7*4.718.2*5.8
T200-75338958019514.7*5.618.2*6.8
T200-90338958519514.7*6.718.2*8.2
T200-110338958519514.7*8.118.2*10
T200-160368958520014.7*11.818.2*14.6
T225-633651108021016.6*4.720.5*5.8
T225-753651108522016.6*5.620.5*6.8
T225-903651109023016.6*6.720.5*8.2
T225-11036511010023016.6*8.120.5*10.0
T225-16048511011024216.6*11.820.5*14.6
T225-20048511011024216.6*14.720.5*18.2
T250-633651108523518.4*4.722.7*5.8
T250-753651109023518.4*5.622.7*6.8
T250-9036511010024518.4*6.722.7*8.2
T250-11036511011024518.4*8.122.7*10
T250-16050511011025018.4*11.822.7*14.6
T250-20050511011025018.4*14.722.7*18.2
T280-633001009024020.6*4.725.4*5.8
T280-753001009024020.6*5.625.4*6.8
T280-903001009024020.6*6.725.4*8.2
T280-11030010010024020.6*8.125.4*10
T280-16038710010025020.6*11.825.4*14.6
T280-20038710010525020.6*14.725.4*18.2
T280-25053011010526020.6*18.425.4*22.7
T315-633701109027023.2*4.728.6*5.8
T315-753701109027023.2*5.628.6*6.8
T315-9037011010028023.2*6.728.6*8.2
T315-11037011011028023.2*8.128.6*10
T315-16046011011028523.2*11.828.6*14.6
T315-20046011011028523.2*14.728.6*18.2
T315-25057510311028523.2*18.428.6*22.7
T355-9033011010028721.1*5.432.2*8.2
T355-11035011010028721.1*6.632.2*10
T355-16040011010028721.1*9.532.2*14.6
T355-20044011010028721.1*11.932.2*18.2
T355-25049011010028721.1*14.832.21*22.7
T355-31555511010028721.1*18.732.21*28.6
T400-9034011010031023.7*5.436.3*8.2
T400-11036011010031023.7*6.636.3*10
T400-16040011010031023.7*9.536.3*14.6
T400-20045011010031023.7*11.936.3*18.2
T400-25049011010031023.7*14.836.3*22.7
T400-31555511010031023.7*18.736.3*28.6
T400-35559511010031023.7*21.136.3*32.2
T450-9037512012036526.7*5.440.9*8.2
T450-11037512012036526.7*6.640.9*10
T450-12546415012036526.7*7.440.9*11.4
T450-16046413012036526.7*9.540.9*14.6
T450-20046412012036526.7*11.940.9*18.2
T450-22554515013037526.7*13.440.9*20.5
T450-25054514013037526.7*14.840.9*22.7
T450-28060014014038526.7*16.640.9*25.4
T450-31560013014038526.7*18.740.9*28.6
T450-35566014016040526.7*21.140.9*32.2
T450-40067012016040526.7*23.745.4*36.3
T500-11039813013542029.7*6.645.4*10
T500-16049514013542029.7*9.545.4*14.6
T500-20049513513542029.7*11.945.4*18.2
T500-22554515013542029.7*13.445.4*20.5
T500-25054513513542029.7*14.845.4*22.7
T500-28063015514543029.7*16.645.4*25.4
T500-31563514514543029.7*18.745.4*28.6
T500-35570015016044529.7*21.145.4*32.2
T500-40070514016044529.7*23.745.4*36.3
T500-45080015017045529.7*26.745.4*40.9

HDPE electric fusion reducing tee is a high-performance pipe fitting using electric fusion connection technology, specially designed for branch reducing connection of HDPE pipeline system. The product has built-in high-precision electric heating wire, which realizes molecular-level fusion of pipes and fittings through electric heating, forming a high-strength, zero-leakage integrated structure, which is particularly suitable for engineering scenarios with limited construction space or requiring rapid installation.

HDPE Electrofusion reducing tee (1)
HDPE Electrofusion reducing tee (1)

Product core advantages

1. Intelligent electric fusion connection-built-in resistance wire, automatic fusion when powered on, more convenient construction, reducing human errors

2. 100% leakage-molecular fusion, interface strength ≥ pipe body, completely eliminating leakage risk

3. Flexible configuration of reducing diameters-supports multiple caliber combinations (such as DN200×DN110×DN200), adapting to complex pipe network requirements

4. All-weather construction-stable construction can be carried out in -40℃~+50℃ environment, not affected by weather

5. Ultra-long service life-high-quality PE100 raw materials, corrosion-resistant, anti-aging, service life of more than 50 years

Application areas

1. Municipal engineering: water supply and drainage network branch transformation, rainwater and sewage diversion system

2. Gas transmission: urban gas network reducer connection

3. Industrial pipeline: chemical medium transportation, factory process pipeline

4. Mining engineering: slurry transportation pipeline system

5. Agricultural irrigation: diversion control of large sprinkler system

HDPE Electrofusion reducing tee (2)
HDPE Electrofusion reducing tee (2)

Intelligent electric fusion connection system

1. Automatic identification: the pipe fittings have built-in scannable barcodes, and the welding parameters are automatically matched

2. Precise temperature control: the intelligent electric fusion welding machine monitors the welding process in real time

3. Double protection: over-temperature protection + current protection to ensure construction safety

4. Data recording: optional data recorder, full traceability

Construction points

1. The oxide layer must be removed from the pipe end with a special scraper

2. Ensure that the assembly gap between the pipe and the pipe fitting is ≤0.5mm

3. Use the original HDPE ElectroFusion Welding Machine for operation

4. After welding, natural cooling is required, and forced cooling is strictly prohibited

HDPE Electrofusion reducing tee (3)
HDPE Electrofusion reducing tee (3)

Specification

dnDLL1L2L3SDRWeight
Sizemmmmmmmmmm kg
40*25571364648115SDR110.202
40*32571364652119SDR110.188
50*25651505042117SDR110.214
50*32651505045120SDR110.224
50*40651505050125SDR110.245
63*25821755542135SDR110.395
63*32821465545138SDR110.296
63*40821465550142SDR110.321
63*50821565556148SDR110.365
75*32951526045150SDR110.428
75*40951606050155SDR110.439
75*50951686056162SDR110.51
75*63951786066172SDR110.554
90*321121646545168SDR110.575
90*401121706550172SDR110.612
90*501121786556178SDR110.656
90*631121886566188SDR110.736
90*751121986571193SDR110.811
110*321351757345190SDR110.92
110*401351837350195SDR110.938
110*501351947356200SDR110.979
110*631352057366210SDR111.108
110*751352157371215SDR111.163
110*901352287380225SDR111.173
160*631942288466270SDR112.186
160*751942388471275SDR112.346
        
dnDLL1L2L3SDRWeight
Sizemmmmmmmmmm kg
160*901942528480284SDR112.448
160*1101942708483288SDR112.759
200*632402589866318SDR113.621
200*752402689871325SDR113.774
200*902402809880333SDR113.937
200*1102402969883342SDR114.233
200*1602403389899455SDR115.253
250*9029930011580395SDR116.447
250*11029931811583398SDR116.783
250*16029936011599412SDR118.313
250*200299392115113425SDR119.129
315*11037833812083475SDR1111.3
315*16037837812099495SDR1113
315*200378410120113510SDR1115.1
315*250378450120130514SDR1117.34
355*200427490164112560SDR1120.5
355*250427490142129580SDR1122.9
355*315427570157150600SDR1126.8
400*200482460150112608SDR1126.65
400*250482505150129625SDR1129.85
400*315482560150150652SDR1134.71
450*250514550160129655SDR1726.27
450*315514606160150682SDR1730.96
450*400514680160180713SDR1740.88

What is the difference between a tee and a reducing tee?

1. Basic structural differences

Comparison ItemStandard HDPE TeeHDPE Reducing Tee (Reducer Tee)
Pipe Diameter DesignMain & branch pipes share same diameter (e.g. DN110×DN110×DN110)Main & branch pipes have different diameters (e.g. DN160×DN90×DN160)
Visual CharacteristicsThree ports with identical diametersAt least one port diameter differs from others
Internal Flow PathUniform diameter with consistent flow resistanceTransitional diameter change may create local vortices

2. Differences in functional use

TypePrimary FunctionTypical Application Scenarios
Standard TeeEqual flow splitting/combining• Equidistant branching in water supply networks
• Symmetrical flow division in drainage systems
Reducing TeeVariable flow distribution/
pressure regulation
• Main pipe to smaller branch diversion (e.g. DN200→DN110)
• Pressure reduction at pump station outlets
• Different flow rate branches in irrigation systems

3. Comparison of hydraulic characteristics

CharacteristicStandard TeeReducing Tee
Flow Resistance CoefficientLower (0.3~0.5)Higher (0.5~1.2, depends on reduction ratio)
Pressure LossRelatively smallMay cause 5%~15% pressure drop at branch end
Flow Velocity ChangeEssentially remains unchangedBranch flow velocity increases as diameter decreases

4. Construction precautions

ItemStandard TeeReducing Tee
Installation OrientationCan be installed in any directionMust follow flow direction arrow (typically main→branch is tapered direction)
Welding ProcessStandard butt/eletrofusion parametersRequires extended heating time at reduction zone (thicker wall section)
Support RequirementsConventional pipe supportsAdditional support recommended at reduction interface


5. Selection recommendations

Ordinary tees are preferred: when the system meets the following conditions

✓ The flow requirements of branch pipes are the same

✓ No need to adjust the branch pipe pressure

✓ The pipeline space layout allows equal diameter connection

Different diameter tees must be used: when the following requirements occur

✓ The main pipeline is diverted to the small flow branch (such as the connection of the community water supply main pipe to the household pipe)

✓ The branch pipe pressure needs to be reduced (such as the pressure reduction of the irrigation system)

✓ The pipeline space is limited and the diameter transition is required (such as the change of pipe diameter when crossing the structure)

Contact Us Right Now